In principle
Your stove is tted with Primary and Secondary air inlets.
Primary Air is controlled using the lever situated under the ash lip of the stove. Moving the con-
trol lever into a downward position will open the air inlet and will allow a supply of preheated
air to enter the rebox via the ‘airwash’ system situated inside the stove and the above glass.
Secondary Air is delivered to the rebox using the specially designed bae at the back of the re-
box. The secondary air is injected into the ue gases both above and in front of the re resulting in
a cleaner, more ecient combustion process. The supply of secondary air is xed open and is not
adjustable. The lower air controler on the door is xed, and only for decoration purposes.
For extra safety, your stove has been tted with a removable handle. When not in use the
handle can be stored using the lug behind the right leg of the stove.
2.2 Lighting and loading intervals
When rst lighting the stove, a large volume of air is needed. When the stove is cold, you
should leave the door open an inch or two for the rst few minutes and open the primary air
supply completely. While the door is open, do not leave the stove unattended.
To form a reasonable bed of ash on the oor of the stove, you should use 5-6 inches thick-
ness (2-4 pound) of dry kindling at the initial lighting. Always maintain a 1-1,5 inch (2-3 cm)
layer of ash on the oor of the combustion chamber at all other times.
1. The air supply must be fully open.
2. Light the re. An ember bed will quickly be formed by light-
ing with relighters, Morsø kindling bags or 7-10 pieces of twist-
ed paper under the dry kindling wood (see above).
3. After lighting, partially close the door, leaving it open an
inch or two to allow in plenty of combustion air.