E05 Indicates the information prompt of the over-current protection
of the down-control motor.
E05
Solutions
to
Common
Problems
The load of the walking machine
exceeds the rated operating
current of the motor
It is recommended to be
within the rated operating
current range of the motor
There is a problem with the
assembly structure of the
walking machine and the motor,
resulting in motor resistance or
blockage
Check whether the
structure of the walking
machine is normal
Lower control current
limiting system failure
Replace the lower control,
pending maintenance
E06 Indicates that the voltage of the drive power supply for the
down-control test is too low and the abnormal phenomenon prompts.
E06
Solutions to
Common
Problems
The supply voltage is too low
Please check whether the
power supply line is normal
The test circuit of the lower
control board fails
Replace the lower control,
pending maintenance
E07 or ---- The electronic watch safety lock is not put in the prompt.
Note: The machine will prompt maintenance when it runs for 50 kilometers. After the
cumulative running distance of the machine reaches 50 kilometers, the maintenance icon
lights up during the running process. At this time, please perform maintenance on the
walking machine. After maintenance, power on the machine and the safety lock falls off,
press and hold the speed.
E07
Solutions to
Common
Problems
Safety magnet trip
Please put the safety lock on
the designated position of the
electronic watch
Electronic watch safety lock
system failure
Replace the electronic watch,
pending repair