G) T. PAUSA Flashing beacon ON/OFF
H) RIT. ANTE Flashing beacon ON/OFF
A) AUT / P-P (Remote programming of radio control) :
The control unit allows for programming the transmission code
from remote, without using the SEL key.
To programme the transmission code from remote follow this
procedure: send the radio control code continuously for more
than 10 seconds, the control unit enters the programming
mode as illustrated above for the CODE LED in the main menu.
The control unit is supplied by the manufacturer with the
remote programming of the transmission code not enabled; to
enable the function follow this procedure: check that the
extended menu is enabled (T. PAUSA and RIT. ANTE LED’s
flashing alternatively), with the SEL key go to AUT/P-P LED
when flashing and press the SET key: the AUT/P-P LED turns
on and programming is completed. Repeat the operation to
restore the previous configuration.
B) CODE (Photoelectric Cells Test):
The control unit is supplied by the manufacturer with the
photoelectric cells test enabled (in compliance with EN 12453);
to disable the function follow this procedure: check that the
extended menu is enabled (T. PAUSA and RIT. ANTE LED’s
flashing alternatively), with the SEL key go to CODE LED when
flashing and press the SET key: the CODE LED turns on and
programming is completed. The photoelectric cells test is not
performed; also if they are not connected (DS1 and DS2 inputs
must be bridged) the control unit is enabled for operation.
Repeat the operation to restore the previous configuration.
C) CODE PED: (Maintenance of Hydraulic Motor Pressure):
The control unit is supplied by the manufacturer with the
maintenance of hydraulic motor pressure not enabled. To
enable the function follow this procedure: check that the
extended menu is enabled (T. PAUSA and RIT. ANTE LED’s
flashing alternatively), with the SEL key go to CODE PED LED
when flashing and press the SET key: the CODE PED LED
turns on and programming is completed. In this way the control
unit will send a closing command to the motor every 2 hours for
2 seconds. Repeat the operation to restore the previous
configuration.
D) INB. CMD. AP (The aries (ramming) effect ) :
The control unit is supplied by the manufacturer with the aries
(ramming) effect function not enabled. To enable the function
follow this procedure: check that the extended menu is enabled
(T. PAUSA and RIT. ANTE LED’s flashing alternatively), with
the SEL key go to INB. CMD. AP. LED when flashing and press
the SET key: the INB. CMD. AP. LED turns on and
programming is completed. In this way the lock can be
unlocked and the opening operation can be performed
correctly. Before starting opening the control unit will send a
closing command for 2 seconds.
Repeat the operation to restore the previous configuration.
E) T. MOT. (Closure Strike) :
The control unit is supplied by the manufacturer with the
closure strike function not enabled. To enable the function
follow this procedure: check that the extended menu is enabled
(T. PAUSA and RIT. ANTE LED’s flashing alternatively), with
the SEL key go to T. MOT. LED when flashing and press the
SET key: the T. MOT. LED turns on and programming is
complete. If Deceleration during closing is programmed, the
control unit will add 1-sec time at maximum power (after
completing the decelerated closing operation) in order to
overcome the lock, if present. Repeat the operation to restore
the previous configuration.
F) T. MOT. PED. ( Safety device 2 / Stop input ):
The control unit is supplied by the manufacturer with the safety
Stop input function disabled. To enable the function follow this
procedure: check that the extended menu is enabled (T.
PAUSA and RIT. ANTE LED’s flashing alternatively), with the
SEL key go to T. MOT. PED. LED when flashing and press the
SET key: the T. MOT. PED. LED turns on and programming is
complete. In this way, the control unit changes the operation of
Safety Device 2 ( CN2 no. 9-10 ) to the safety Stop input
operation, as following: acting on any stage of the operation
stops motion immediately. An additional motion command will
be valid as long as the Stop input is deactivated, and in any
case it will close the gate with 5-second pre-flashing.
RESET :
To reset the default configuration, press the SEL and SET keys
simultaneously, all RED LED’s will turn on and then off.
DIAGNOSTICS:
Photoelectric Cells Test:
The control unit is set for the connection of safety devices
compliant with 5.1.1.6 section of EN 12453. The operation test
of connected photoelectric cells is performed at each
manoeuvring cycle. In case of no connection and/or no
operation, the control unit will not enable motion and will
visually indicate the test failure with simultaneous flashing of all
LED’s. Once the correct operation of the photoelectric cells has
been restored, the control unit is ready for operation. This
guarantees monitoring against failures in compliance with
Category 2 of EN 954-1.
Commands input test:
The control unit is provided with a LED for each low voltage
command input to monitor the status immediately.
Operation principle: LED on = input closed, LED off = input
open.
FOR THE USER - IMPORTANT
- The device should not be used by children or by individuals
with reduced physical or psychological abilities unless
supervision is provided or instruction given on how to operate
it.
- Do not let children play with the device; keep radio controls
out of their reach.
- CAUTION: Keep this instruction manual in a safe place and
adhere to the important safety instructions contained within it.
Non-adherence to these instructions may lead to property
damage and serious accidents.
- Examine the system frequently to check for any signs of
damage. Do not use the device if it needs to be repaired.
Warning
All operations which require the casing to be opened (such as
wire connection, programming, etc.) must be carried out during
installation, by skilled staff only.
For any other procedure which requires the casing to be
opened again (programming, repairs or site modifications),
please contact the technical assistance service.