FOR THE INSTALLER - IMPORTANT
− Before the gate automation, it is necessary to check the
good condition of the gate and its compliance with EN
12604 with respect to directive on machines.
− The control unit is not equipped with 230 Vac electric
line sectioning device. The installer is responsible for
installing a sectioning device in the system. The
sectioning device must be protected against accidental
closing in compliance with 5.2.9 section of EN 12453.
− Wiring of external electrical components must comply
with EN 60204-1 as amended in section 5.2.7 of EN
12453. The fixing of power supply leads and connection
cables must be secured through the use of cable
clamps supplied on demand.
− When drilling holes in the outer casing for the power
supply and connection wiring, and when fitting the
cable clamps, make sure everything is installed so as to
maintain the IP protection degree features as fully as
possible.
Please also make sure that the cables are fixed in
place securely.
− The rear casing is designed for wall installation (it is
designed to have holes so that it may be installed using
rawl plugs, or so that it can be fixed in place using
screws). Plan and apply all the details necessary for the
IP degree to remain unaltered after installation.
− If present, the push-button station for manual control
must be mounted in such a way that the user is not in a
dangerous position.
− The motor reducer used to move the gate must comply
with section 5.2.7. of EN 12453.
− The D.S. Power Supply output must be dedicated to
photoelectric cells power supply. It must not be used for
other applications.
− The control unit tests the operation of photoelectric cells
at every manoeuvring cycle to guarantee protection
against failures of anti-crushing devices of Category 2
in compliance with section 5.1.1.6 of EN 12453.
Therefore, if the safety devices are not connected and/
or operated, the control unit is not enabled for
operation.
− For the correct operation of the radio receiver, if two or
more control units are used, we recommend you to
install the devices at least 3 metres away from each
other.
Stateurop hereby declares that the product below:
Electronic Control Unit:
MC2
comply with the requirements of Directives R&TTE
99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC.
Rel. 1.4 of 29-01-08