5.8
Radio Leak Test
This section discusses radio immersibility concerns, tests, and disassembly and reassembly of the
radios.
5.8.1
Vacuum Leak Test
The vacuum leak test is performed to ensure that the radio is IPx7 compliant. Perform this test after
servicing the radio and before returning the radio to the customer.
The following parts are required to perform a vacuum leak test:
Vacuum Leak Tester
The Vacuum Leak Tester comes with a gauge and a vacuum hose. Purchase the Vacuum Leak Tester
from the following supplier:
Supplier:
Horizon Land Malaysia Sdn. Bhd.
Website:
www.horizon-land.com
Contact:
+604-6463636
Model Description:
Horizon Land Delta Version TC-2000
Other items required for the test include:
Table 29: Other Vacuum Leak Test Parts
Part Number Description
HW001772A01 Leak Test Spacer
LB001049A01 Ventilation Label
3286058L01 GORE
®
Membrane
Leak Test Fixture
A Leak Test Fixture is also required for the vacuum leak test. Purchase the Leak Test Fixture from the
following supplier:
Supplier:
Access Hitech Automation Sdn. Bhd.
Website:
www.accesshitech.com
Contact:
Steven Boey
Mobile: +6012-5808783
Email: stevenboey@accesshitech.com or hq@accesshitech.com
Office: +604-6261700
Fax: +604-6261708
MN004528A01-AF
Chapter 5: Maintenance
90