EasyManua.ls Logo

Motorola solutions ST7500 - Performing Vacuum Leak Test; Figure 53: Vacuum Leak Test Setup

Motorola solutions ST7500
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motorola Solutions Part Number:
TL000116A01
Supplier Part Number:
MT057#17
5.8.1.1
Performing Vacuum Leak Test
This test is performed to determine if the radio is properly sealed.
Prerequisites:
Remove the antenna, side escutcheon, and battery cover from the radio.
Remove the ventilation label and GORE membrane.
Cover the vent hole with the leak test spacer, ensuring no air leak through the spacer seal.
Reassemble the battery cover.
Procedure:
1 Attach the vacuum hose to the vacuum leak tester.
2 To verify that the leak tester is functioning, check the leak tester and the hose for leaks by
blocking off the open end of the hose and operating the leak tester a few times.
3 Ensure that the difference between the maximum and minimum fluctuation readings of the
gauge pointer remains within 0.05 inHg.
NOTICE: The actual reading of the gauge pointer at this point is not important.
Figure 53: Vacuum Leak Test Setup
Compressor
Direction of air flow
Radio
Leak
Tester
4 Block the open end of the hose and adjust the leak tester so that the gauge shows 3.30 inHg.
5 Attach the open end of the hose to the leak text fixture.
6 Ensure that the suction cup on the radio leak test fixture is in good condition (no damage or
dust).
7 Place the radio in the leak test fixture with the battery cover facing upwards.
8 Push down the handle of the fixture plate.