6802800U74-AN
Chapter 13: MTS Troubleshooting
========================== BR Status Information
===========================
13.1.4
Verifying Permanent Lock
Verify if the site is permanently locked before antenna maintenance work. Permanent lock is
maintained after resets and power cycles.
Prerequisites: You must be remotely logged on to the MTS.
Procedure:
1 In the Site Controller application, enter status sc.
The output containing the information: Internal State: AS_L_E_IDL (Permanently
Locked) appears.
2 Enter status br.
A list of BR statuses appears:
Cab TX
& Pos Keyed
Address
3 Verify that the BRs' TX Freq and RX Freq equals 000.0000.
If any of the system outputs deviate from the description, the site is not permanently locked. For
details, see “Lock” in the MTS Man Machine Interface Commands manual.
13.1.5
Unlocking the Site from the Permanent Lock State
Follow this procedure to turn off the permanent lock after antenna maintenance work is completed.
Permanent lock is maintained after resets and power cycles.
Prerequisites: You must be remotely logged on to the MTS.
Procedure:
1 Verify that antenna maintenance work is completed.
2 Ensure that no maintenance works are currently performed.
3 To unlock the site:
a Enter: unlock -p
b If it is safe to unlock the site, when prompted for confirmation, enter: Y
The site is unlocked.