TEST SETUP & TESTING for 380–430 MHz and 410–470 MHz 5.1 - 3
Test Check List
The following table summarises the required test setups.
Table 5.1-2    Test Setup 
No. Test Name Test Setup Terminal Setup Test Conditions Limits
1. IFR System  Setup 
and Manual Test 
Screen
Control Channel For 380–430MHz 
terminal: 840
For 410–470MHz 
terminal: 2440
Traffic Channel For 380–430MHz 
terminal: 840
For 410–470MHz 
terminal: 2440
Time Slot 3
Country Code 262
Network Code 75
Base Color 1
Location Area 224
Min Rx Level -110dBm
Max Tx Level 35dBm (3.2W)
Access 
Parameter
-33dBm
Mobile Power 35dBm (3.2W)
Burst Type Normal
2. Base Station
Registration
RF Gen Level For 380–430MHz 
terminal: 
421.0125MHz
For 410–470MHz 
terminal: 
461.0125MHz
-90dBm
3. Receiver RSSI RF Gen Level Cells Info
RSSI
TRACE
-90dBm
4. Transmitter Tests RF Gen Level  Range 1
Test Group 1
-90dBm
Burst Power 33–37dBm
Timing Error <=0.25 Symbols
Frequency 
Error
-/+ 100Hz
Vector Error Max 10% RMS, 
Max 30% Peak,
Max 5% Residual