3.
OPERATIONAL
PROCEDURES)
A.
FUEL TYPE:
Use
only
crystal
clear
Type
1-K
Kerosene.
B.
FUEL
SUPPLY
Precaution
-
No
water
or
debris should
be
allowed
to
enter
the
fuel
tank.
When these
two
are
mixed
with
fuel, imperfect combustion
can
result thereby shortening
the
life
of
the
burner.
1.
Keep
the
tank filter
cap
tight.
2.
Do not
allow
tank
to run
empty.
If
the
KWH124
is
allowed
to
operate
without
fuel,
air
must
be
purged
in the
following
manner:
a.
Refill
kerosene
tank.
b.
Allow
30
minutes after refilling
to
activate
KWH124.
(This
allows fuel
to
settle.)
Fuel
purge
screw
c.
Make sure tank vent
is
open.
d.
Open
shut-off
valve
on
fuel
tank.
Loosen
air
purge screw
at
fuel filter.
Discharge
air out of all
channels
through
which fuel runs.
e.
Fill
the
bowl
of the
unit
fuel
filter
with
kerosene.
Fasten
fuel purge screw back
in
original position.
Handle
O
—Ring
of
fuel purge
screw
carefully.
A
damaged
0
—Ring
can
cause
fuel leakage
and
render
unit
inoperative. Don't misplace
0
—Ring.
f.
Wipe
all
fuel spills
off
thoroughly.
-5-