14
Program
Description
Options
03
Absorption voltage
14.10V (Default)
If Use-Defined is selected
in program 02, this program
can be set up. The setting
range is from 12.00V to
15.00V.
If this program is
selected to modify,
the changeable
figure will be
shown as below.
Increment of each short
press is 0.01. Once the
value is achieved 15.00V, the
value will jump back to
12.00V.
04
Float voltage
13.5V (Default)
If Use-Defined is selected
in program 02, this program
can be set up. The setting
range is from 12.00V to
15.00V.
If this program is
selected to modify,
the changeable
figure will be
shown as below.
Increment of each short
press is 0.01V. The value will
jump back to 12.00V after
15.00V is achieved.
05
Battery rated voltage
Auto (Default)
If AUO is selected,
connected battery voltage
system will be automatically
detected.
12V
If 12V is selected, the unit
is considered as 12V battery
system.
24V
If 24V is selected, the unit
is considered as 24V battery
system.
48V
If 48V is selected, the unit
is considered as 48V battery
system.
06
Battery C.V. charging
duration
150 minutes
(Default)
The setting range is from 5
minutes to 900 minutes.
Increment of each short
press is 5 minutes. It will
jump back to 5minutes after
900 is achieved.