25
8. SPECIFICATIONS
Table 1 Electrical Specifications
MODEL
MPPT 3KW
Nominal System Voltage
12, 24, or 48 VDC (Auto detection)
Maximum Battery Current
60 Amps
Maximum Solar Input
Voltage
145V
PV Array MPPT Voltage
Range
60~115VDC
Maximum Input Power
12 Volt--800 Watts
24 Volt--1600 Watts
48 Volt--3200 Watts
PV Array voltage & Battery
current
Array Voltage (Volts)
110 115 120 125 130 135 140 145 150
Battery Current (Amps)
0
10
20
30
40
50
60
70
Heatsink temperature &
Battery current
Heatsink Temperature
(degrees C)
60 65 70 75 80 85 90 95
Battery Current (Amps)
0
10
20
30
40
50
60
70
Transient Surge Protection
4500 Watts / port