Indicate charging current.
Indicates battery level by 0-24%, 25-49%, 50-74% and
75-100% in battery mode and charging status in line
mode.
Constant
Current
mode /
Constant
Voltage
mode
4 bars will flash in turns.
The right bar will be on and the
other three bars will flash in turns.
The two right bars will be on and
the other two bars will flash in
turns.
The three right bars will be on and
the left bar will flash.
Batteries are fully
charged.
4.4 LCD setting
After pressing button for 3 seconds, the unit will enter setting mode. Shortly press
button to select setting programs. And then, pressing button for at least 1.5 seconds to
confirm the selected program. After that, shortly press button to modify the parameter
of the program. If pressing button for at least 1.5 seconds, you will return to previous
menu. After waiting for 10 seconds without any action, it will automatically exit setting
mode.
Setting Programs:
Setting range is from 10A to
60A. Increment of each short
press is 1A. The value will be
back to 10A once the value is
achieved 60A.
If “Use-Defined” is selected,
battery charge voltage can
be set up in program 3 and 4.