DONNING
INSTALLING THE SLIDE-TO-CONNECT FIREHAWK
R
EGULATOR ON THE FACEPIECE
N
OTE: The slide-to-connect regulator has a side button
with a two pronged fork protruding from it. If this “fork” is
not present refer to the Installing the Push-To-Connect
Firehawk Regulator section of this manual.
1. Grasp and orient the
regulator so that red
bypass knob is point-
ing to the right and
slide button is on top.
2. Slide the regulator onto
the rail of the facepiece
cover. Slide the regula-
tor down the rail until
the regulator stops.
3. Insert the regulator into
the facepiece inlet by
pushing inward.
4. Ensure proper engagement by pulling on the regulator
to verify that the regulator is securely attached to
facepiece.
DO NOT use the air mask unless the Firehawk
Regulator is connected properly. A regulator that is
not installed correctly can separate from the facepiece
unexpectedly. Return the air mask to an MSA trained
or certified repairperson to correct the condition.
Misuse can result in serious injury or death.
5. Inhale sharply to start the airflow.
a
. Check the bypass again by turning the red knob
counter-clockwise until increased airflow is felt.
C
lose the bypass.
There must be a continuous flow of air when the
b
ypass knob is opened. If not, do not use the air
mask. The air mask must be checked and the condi-
tion corrected by an MSA trained or certified repair-
person before it can be used. Misuse can result in
serious injury or death.
NOTE: If the air mask passes all tests, it is ready for use.
These tests must be performed every time before entering
a hazardous atmosphere. If the air mask fails to meet any
of the tests, the condition(s) must be corrected before
using the air mask.
INSTALLING THE PUSH-TO-CONNECT FIREHAWK
REGULATOR
NOTE: There are two versions (slide-to-connect and
push-to-connect) of the Firehawk Regulator available for
the FireHawk M7 Air Mask. A slide-to-connect Firehawk
Regulator can be identified by examining the side buttons.
The slide-to-connect has a side button with a two
pronged fork protruding from it. If this “fork” is present,
refer to Installing the Slide-To-Connect Firehawk
Regulator section.
1. Grasp the Firehawk Regulator and insert the regulator
into the facepiece by pushing inward. Check proper
engagement by pulling on the regulator to ensure that
the regulator is securely attached to facepiece.
DO NOT use the air mask unless the regulator is con-
nected properly. A regulator that is not installed correct-
ly can separate from the facepiece unexpectedly. Return
the air mask to an MSA trained or certified repairperson
to correct the condition. Misuse can result in serious
injury or death.
2. Inhale sharply to start the airflow.
3. Check the bypass again by turning the red knob
counter-clockwise until increased air flow is felt. Close
the bypass.
There must be a continuous flow of air when the
bypass knob is opened. If not, do not use the air
mask. The air mask must be checked and the condi-
tion corrected by an MSA trained or certified repair-
person before it can be used. Misuse can result in
serious injury or death.