not be fully charged and the capacity of the batteries will be too low for your
application, resulting in premature wear. If the charging current is too high,
or if the duration of the charging process is too long, the battery can be overcharged. As a result, the
plates of your battery will overheat and may become damaged.
Intermediate charging
If, for example, the batteries are empty for only 60% and are reconnected to the charger, the
batteries will not get the time to relax. The temperature of the batteries will increase, resulting in
premature wear. Also, the voltage of the battery will become higher than the actual energy
condition, which means that the discharge limiter will no longer work correctly.
Ambient temperature
The temperature of the battery may not get too high, as the acid will become more aggressive. Here,
we are thinking of greenhouses and other heated spaces.
Frequent use
If, every 7 days, the batteries are used on more than 4 days, they will also wear more quickly. When
selecting batteries, it is important to take into account the Multi-Mover M's frequency of use.
Sulphation
A battery will slowly discharge as a result of automatic discharge. If a battery remains in a discharged
condition, it will start to sulphate and become damaged beyond repair. We therefore recommend
recharging the stored Multi-Mover M every 2 months.
It is also possible, that there are still standby consumers in a switched off Multi-Mover M (key
ignition etc.), which will mean that the batteries will discharge more quickly.
In that case, regular recharging of the batteries is recommended.
Immediate recharging of an empty battery, significantly promotes a longer life span. Further
discharging than 20% has a negative effect on the life span.
The gases that are released while charging the battery are highly explosive (detonating gas).
Therefore, avoid fire and sparks near the charging location.
Charging may only take place in a well ventilated room.
Regularly check whether the battery charger stops automatically when the battery is full.
Never interrupt the charging process, make sure it is fully completed.
While charging the battery, never perform repair, cleaning or other work to the Multi-Mover M.
Prior to disassembling the batteries, switch off all power consumers, because of the generation of
sparks.
When disassembling the batteries, first disconnect the mass cable (-)
When assembling, connect the mass cable as last.
Caution! Always plus ( + = red) to plus and minus (- = black) to minus
Battery fluid is a corrosive acid, avoid contact with clothing, skin and eyes.
Immediately wash off possible splashes on clothes or skin with water and soap, then rinse off with
plenty of water. Possible splashes of acid in the eyes, rinse with clean water for at least 5 minutes
and immediately consult a doctor.