EasyManua.ls Logo

Multi-Power MP7500E - Emptying the Gas Tank; Storage; Transport Procedures

Multi-Power MP7500E
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Emptying the Gas Tank
Before storing the generator for extended periods of time, you should drain the generator of gasoli ne.
To drain the generator of gas:
1. Turn the fuel valve to the “off” position.
2. Remove the fuel filter cup (see “ Fuel Filter Cup Cleaning ” earlier in this section ).
3. Empty the fuel filter cup of any fuel.
4. With a receptacle underneath the generator to catch t he gas, turn the fuel valve to the “on”
position. Drain all the gas from the generator.
5. Turn the fuel valve to the “off” position.
6. Replace the fuel filter cup.
7. Store the emptied gasoline in a suitable place.
CAUTION: Do not store fuel from one season to another.
STORAGE / TRANSPORT PROCEDURES
CAUTION: Never place any type of storage cover on the generator while it is still hot.
When transporting or storing the generator for extended periods of time:
Empty the gas tank (see “Emptying the Gas Ta nk” in the “Maintenance” section).
Disconnect the spark plug cap from the spark plug.
Do not obstruct any ventilation openings.
Keep the generator in a cool dry area.