Installation Section 2
2-4 Part Number 000003912 6/17
Location Requirements
SODA REFRIGERATION UNIT “QUICK-PICK” SELECTION CHART
CLEARANCES
RATINGS
Select a location for the refrigeration unit that meets the
requirements of the building plans, local codes, and
personnel. The unit must be positioned for free airflow
as well as for future service. The following requirements
must be met:
• 100 GPH (379 LTR/hr) potable water supply Models
2803/11/38; 200 GPH (757 LTR/hr) potable water
supply Models 44/50
• Beverage quality CO
2
gas (bulk or bottled supply)
with a minimum 3/8" (.96 cm) line
• One Bag-In-Box (BIB) container of each post mix
syrup flavor.
NOTE: Refer to nameplate on side of refrigeration unit
for voltage and amperage specifications. Make all
electrical connections at the junction box located at the
top rear of unit. Optional equipment may require
additional power supplies.
NOTE: Potable water connections to the equipment
must comply with local plumbing code requirements,
particularly the back-flow prevention requirements.
Number of Dispensing Stations
Business Level* 1 2 3 4
Up to 6 gal / 3 L
of syrup/day or
280 drinks/day
(2,000 gal/yr)
Model 2803
40 ft / 12 m
Maximum
Conduit Length
Model 11M
100 ft / 30 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Up to 12 gal / 45 L
of syrup/day or
560 drinks/day
(4,000 gal/year)
Model 11M
100 ft / 30 m
Maximum
Conduit Length
Model 11M
100 ft / 30 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Up to 21 gal / 79 L
of syrup/day or
980 drinks/day
(7,500 gal/yr)
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Up to 32 gal / 121 L
of syrup/day or
1400 drinks/day
(11,500 gal/yr)
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 44M
250 ft / 80 m
Maximum
Conduit Length
Model 50M
350 ft / 107 m
Maximum
Conduit Length
Model 50M
350 ft / 107 m
Maximum
Conduit Length
Up to 42 gal / 159 L
of syrup/day or
2000 drinks/day
(15,000 gal/yr)
Model 50M
350 ft / 107 m
Maximum
Conduit Length
Model 50M
350 ft / 107 m
Maximum
Conduit Length
Model 50M
350 ft / 107 m
Maximum
Conduit Length
Model 50M
350 ft / 107 m
Maximum
Conduit Length
* Care must be taken when selecting the proper refrigeration unit. Above selections are for 75°F (24°C) conditions, 16 ounce (470 ml) drinks, and average business
cycles. Other factors such as lunch or dinner peak periods, large drinks, or high ambient conditions may require the next larger size unit. Contact your Manitowoc
Company Authorized Distributor or Manitowoc Beverage Systems (MBS) for more information.
Control Side (Right) 18" (45.7 cm)
Tower Connection Side (Left) 12" (30.5 cm)
Back Side 6" (15.2 cm)
Ceiling 18" (45.7 cm)
Model
Evaporator Rating
at 20°F (-6.5°C)
Heat Rejection (Max.)
Model 2803 &
SC180
2,500 BTUH
490 kcal/hr
4,500 BTUH
885 kcal/hr
Model 11M &
SC340
5,150 BTUH
1,159 kcal/hr
8,638 BTUH
1,949 kcal/hr
Model 44M &
SC1000
9,700 BTUH
2,340 kcal/hr
13,576 BTUH
3,685 kcal/hr
Model 50M &
SC2000
14,900 BTUH
3,310 kcal/hr
20,400 BTUH
4,285 kcal/hr