Installation Section 2
2-6 Part Number 000003912 6/17
Electrical
GENERAL
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit
ampacity is not the beverage/ice machine’s running amp
load.) The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Ice Machine Model/Serial Plate for
voltage/amperage specifications.
SPECIFICATIONS
* Only the model 50M with SS part numbers have 120V components, the TS does not.
!
Warning
All wiring must conform to local, state and national
codes.
Model Volt/Cycle/Phase Minimum Circuit Amps Breaker Compressor
2803 & SC180 120/60/1
230/50/1
20.3
9.0
25A
16A
1/3 hp
.46 kW
11M & SC340 120/60/1
230/50/1
21.5
10.7
30A
16A
1/2 hp
.97 kW
44M &
SC1000
208-230/60/1
230/50/1
20.6
20.6
30A
25A
1 hp
1.9 kW
50M 120* /208-230/60/3
230/400/50/3
25.2
11.6
30A
20A
2.2 hp
2.0 kW
SC2000 208-230/60/3
230/400/50/3
25.2
11.6
20A
15A
2.2 hp
2.0 kW