4. When the python and tower are connected, open the mains water inlet supply and
visually check the unit internally and externally for leaks. Repair any leaking joints.
5. Open the CO
2
inlet supply to the unit, again checking for leaks, and repair any
leaking joints.
6. Whenyouarehappytherearenoleaks,replacethetopcover,andxwiththe
securing screws.
7. Switch on the mains power supply. Note: the unit does not have a mains ON/OFF
switch – to electrically isolate the unit, disconnect the plug from the mains socket at
the wall.
8. The compressor and condenser fans will start as soon as the mains power is
connected.
9. Thecarbonatorpumpwillinitiateacarbonatorllcycle.Thisshouldtakenomore
than 30 seconds. Note: If the carbonator bowl fails to ll in 45 seconds, the pump
will switch o and the red LED on the front of the unit will ash. This is an indication of
low/no water ow to the carb bowl. Turn o the power at the mains, and investigate
and correct the water ow problem. After the full water ow has been restored, the fault
condition may be cleared by switching the power back on at the mains.
10. Check for leaks at the python connections between the cooler and tower. Repair
any leaking joints.
11. Primethedispenselinesbydrawingodrinksatthedispensevalves,untilboththe
stillandcarbonatedwaterowsaresteady.
12. The system is ready for use when the cooler cuts-out after Initial Pull Down.