Section 6
01-3001-xx Hyper Warwick Water Cooled
BLACK
BLUE
GN/YLW
RED
1.50mm2 BLACK TRI CORE CABLE 2.5M TOTAL LENGTH
MOULDED PLUG 13 AMP FUSE
BROWN
BLACK
BLUE
BROWN
BLUE
BROWN
BLUE
GRN/YLW
BROWN
RED
GRN/YLW
IEC SOCKET
GLYCOL MODULE
POWER
COMPRESSOR NEUTRAL
DFX
SERIES 1E
CONTROLLER
SW LIVE
LIVE 2
LIVE
NEUTRAL
PROBE 1
PROBE 2
PROBE
GREEN
NEON
SLIDER
SWITCH
RED
NEON
IEC SOCKET
CARBONATOR
POWER
BROWN
BLUE
GRN/YLW
COMPRESSOR LIVE
COMPRESSOR EARTH
BROWN
BLUE
GRN/YLW
AGITATOR
MOTOR
CONNECTION
BOX FAN NEUTRAL
BOX FAN LIVE
BOX FAN EARTH
BLUE
BROWN
GN/YLW
HYPER WARWICK R290 WIRING SCHEMATIC (WATER COOLED)
COMPRESSOR
BOX FAN
SODA
RE-CIRC PUMP
BROWN
BLUE
PUMP LIVE
PUMP NEUTRAL
GRN/YLW
PUMP EARTH
RED
BROWN
BLUE