38
MultiMobile
USB
User Guide
Command: &T
n
V.54 Test Commands
Values:
n
= 0, 1, 3 or 6
Default: None
Description: &T0 Abort. Stop any test in progress.
&T1 Local analog loopback test.
&T3 Local digital loopback test.
&T6 Remote digital loopback test.
Note: To stop a test, you must use the escape sequence (+++AT) before typing AT&T0.
Command: &V Display Current Settings
Values: n/a
Description: Displays the active modem settings, including the callback security settings if callback security
is enabled. If the setup password has been entered, it also displays the callback security pass-
words.
Command: &W
n
Store Current Configuration
Values:
n
= 0
Default: None
Description: &W0 Stores current modem settings in nonvolatile memory and causes them to be loaded at power-on
or following the ATZ command instead of the factory defaults. See also the
&F
command.
&W1 Clears user default settings from nonvolatile memory and causes the factory defaults to be
loaded at power-on or following the ATZ command.
Command: &Y
n
Select Stored Configuration for Hard Reset
Values:
n
= 0
Default: 0
Description: &Y0 Select stored configuration 0 on power-up. (For backward compatibility with some software.)
&Y1 Not supported—responds
ERROR
.
Command: &Zy
=x
Store Dialing Command
Values:
y
= 0–1
x = Dialing command
Default: None
Description: Stores dialing command
x
in memory location
y
. Dial the stored number using the command
ATDS=y.
Command: \A
n
Select Maximum MNP Block Size
Values:
n
= 0, 1, 2, or 3
Default: 3
Description: \A0 64-character maximum.
\A1 128-character maximum.
\A2 192-character maximum.
\A3 256-character maximum.
Command: \B
n
Transmit Break
Values:
n
= 0–9 in 100 ms units
Default: 3
Description: In non-error-correction mode only, sends a break signal of the specified length to a remote mo-
dem. Works in conjunction with the
\K
command.