User Manual
Farm Premium, Premium-P,
Premium XL, P-XL
Climate Controllers for Poultry and Pigs
Ag/MIS/UmGB-2224-01/15 Rev. 1.7
P/N: 110476
Farm Premium
Controllers

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Munters Farm Premium XL and is the answer not in the manual?

Munters Farm Premium XL Specifications

General IconGeneral
Display7 inch touch screen
Power Supply24 VDC
Operating Temperature50 °C
Humidity Range0 - 95% RH
Outputsanalog outputs
InputsAnalog and digital inputs

Summary

3 Control Menu

3.1 Temperature Curve

Sets temperature targets according to bird/pig age.

3.2 Introduction to Humidity, Ammonia, and CO2 Treatment

Overview of controlling humidity, CO2, and ammonia levels.

3.3 Humidity Treatment

Increases ventilation when humidity is too high.

3.4 CO2 Treatment

Increases ventilation when CO2 level is too high.

3.5 Min/Max Level

Selects range of ventilation levels based on situation.

3.6 Static Pressure

Sets static pressure targets and alarms.

3.9 Ammonia Treatment

Increases ventilation when ammonia level is too high.

4 Device Menu

4.1 Levels of Ventilation

Sets up to 30 ventilation levels controlling fans.

4.11 Emergency Setting

Settings for optional emergency cards.

4.13 Natural Program

Uses wind to supply house air requirements.

5 Manage Menu

5.5 Alarm Setting

Defines various alarm settings.

6 Scale Menu

8 Test Menu

8.1 Switches & Relays

Displays identified switches and relays to find faulty hardware.

8.8 Hardware Checklist

Checks installed hardware identified by Plug and Play.

9 Service Menu

9.1 Temperature Calibration

Calibrates temperature sensors by adjusting a correction factor.

9.2 Humidity Calibration

Calibrates humidity level using a test kit.

9.3 CO2 Sensor

Calibrates CO2 level using a test kit.

9.4 Static Pressure Calibration

Calibrates the static pressure sensor.

9.5 Light Sensor Calibration

Calibrates the light sensor.

9.6 Feed Calibration

Calibrates digital monitoring devices for feed.

9.7 Water Calibration

Enters quantity of water per pulse for water meters.

9.8 Ventilation Potentiometer Calibration

Calibrates the ventilation potentiometer control.

9.13 Current Sense Relay Calibration

Calibrates the amount of current passing through Current Sense relays.

9.14 Wind Direction Calibration

Calibrates a wind direction sensor.

9.15 WOD Calibration

Calibrates the Water on Demand (WOD) sensor.

9.16 Ammonia Calibration

Calibrates the ammonia level sensor.

10 Install Menu

10.1 Setup

Configures critical parameters like units, language, and modes.

10.2 Relay Layout

Defines devices connected to the controller by mapping relays.

10.3 Analog Sensors

Installs and configures analog sensors like temperature, humidity, CO2.

10.4 Digital Sensors

Configures installed digital sensors for water and feed consumption.

10.5 Analog Output

Controls devices like fans, heaters, dimmers, vents, curtains via analog output.

10.6 Vent / Curtain Setup

Defines ventilation opening/closing mechanism using time, potentiometer, or wind.