7.14.2
C
ONFIGURING THE
S
ILO
S
CALE
The following procedure details how to “zero out” the Trio silo scales. Zeroing out is way to ensure that
the unit’s A2D number is accurate (shown in the Silo Icon; 430 in the picture below). To summarize the
procedure:
The user enters the correct amount of feed in the silo while calibrating the silo scale. In the Silo
management screen, the user enters “0” (zero). Trio then defines the current A2D signal to be
the A2D signal for an empty bin.
1. Define each silo’s storage capacity.
2. Click on the silo icon and click Calibrate. The following screen appears: