00-02-0605 - 28 - Rev 09-10-08
“NO STORED CODES” is displayed
The PowerView sent a request to the ECU for Stored Fault
Code (DM2) information, and the ECU responded. There
are zero stored codes.
“NO GAGE DATA” is displayed
The PowerView has no record of gages connected to the
RS485 bus.
“NO DATA” is displayed in place of a parameter value
The PowerView has not received data for the selected
parameter for at least 5 seconds.
“NOT SUPPORTED” is displayed in place of a parameter
value
The ECU is sending a message that it does not support this
parameter.