SECOND GENERATION SPRINT TRANSMITTER CALIBRATION PROCEDURE
Page 1 of 2
DIAL TO
LEFT
UP (Nor)
POINT UP
Carefully remove and save the cover to the calibra-
tion hole. It is easiest to push out from the inside.
Set the transmitter controls as shown.
POINT TO 5:00
NOTE: Place SPRINT up on blocks in an upright position with the
wheels off the ground before beginning this procedure.