2205Q2JE-HO-S6-N_2020.01. 
Chapter 6 Troubleshooting 
SCV-series Screw Compressors 
6-11 
  Trouble  Direct causes  Factors  Actions 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
substances 
Refer to the Direct cause “Foreign 
substances entering into 
stress 
High suction pres-
sure exceeding 
operating 
Re-examine operating conditions 
and improve them if possible. 
If it is difficult to improve, 
re-examine maintenance interval 
management. 
* Lock nuts 
tightened 
insufficiently, lock 
washer tab not 
bended, etc. 
Tighten lock nuts by using specified 
torque. 
 
Be sure to record data on the 
assembly check sheet to prevent 
omission of work steps. 
vibration 
occurs when the 
natural frequency of 
piping or support 
approaches to 
vibration of 
compressor. 
In many cases, this occurs due to 
change in installation environment 
such as change in piping circuit or 
additional installation of devices in 
the machine room, and changes in 
oil levels. 
→If sympathetic vibration is 
suspected, contact our sales 
offices or service centers.