EasyManua.ls Logo

Myenergi Eddi+ - Page 2

Myenergi Eddi+
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright
Copyright of these instructions remains with the manufacturer.
Text and images correspond to the technical level at the time of
going to press. We reserve the right to make changes. The content
of the operating instructions shall not give rise to any claims on
the part of the purchaser. We are grateful for any suggestions for
improvement and notices of errors in the operating instructions.
myenergi libbi, myenergi zappi, myenergi eddi, myenergi eddi+, myenergi
harvi and myenergi hub are registered trademarks of myenergi ltd.
Liability limitation and Warranty
myenergi do not accept any direct or indirect liability for product or property
loss caused by the following conditions:
Product moded, design changed or parts replaced without authori-
sation.
Changes, repair attempts and erasing of serial numbers or seals by un-
authorised person
System design and installation were not in compliance with standards
and regulations; fail to comply with local safety regulations.
Damage caused by any transportation of the products by the installer.
Failure to follow any and/or all user manuals, installation guides and
maintenance regulations.
Improper use or misuse of the device.
Force majeure (stormy weather, lightning, overvoltage, re etc.)
Damage from external factors.
Safety
Read all the safety instructions. Failure to install and operate the eddi+ in
accordance with these instructions may cause injury or death, damage to
the unit or inefcient operation and invalidate the manufacturer’s warranty.
Manual Keeping
This manual contains important information about operating the device.
Before operating, please read it very carefully.
The device should be operated in strict accordance with the instructions in
this manual. This manual should be kept for future maintenance.
Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
Indicates a notice or ‘tip’ to guide you.
CAUTION
Only have the system installed and commissioned by qualied
personnel with the appropriate skills.
Prior to performing any work on the eddi+, disconnect from all voltage
sources, as described in this document.
Do not install or operate the system in potentially explosive
atmospheres or areas of high humidity.
The unit must be installed indoors and should be mounted to a at
vertical surface or wall, in the vertical orientation only and using the
dedicated mounting bracket which comes attached to the unit.
Do not install the unit in any environment of temperature below -20°C
or over 40°C.
Suitable xings must be used dependant on application/mounting
surface. To be determined by installer.
The supply cord to/from this control can be replaced only by the
manufacturer or his accredited service agent and shall conform to the
requirements of EN 50525-2-11.
This device must be supplied by an upstream 3-pole 16A type A or B
MCB or equivalent overcurrent device..
Only purely resistive loads must be connected to the eddi+ output
terminals.
The unit is not to be used by persons (including children) with reduced
physical, sensory, or mental capabilities, or lack of experience and
knowledge, unless they are supervised or have been given instruction
concerning use of the device by a person responsible for their safety.
The heat sink can exceed 70°C during normal operation, therefore do
not touch.
Do not put any heavy objects on top of the system.
Do not damage the system with sharp objects.
Only use replacement parts supplied or recommended by myenergi.
Replacing of parts must be carried out by a suitably qualied installer.
Under short-circuit conditions, the relays for heaters/outputs 2 and 3
may weld. If power to the device can not be reinstated at the upstream
MCB, please consult your installer for repair or replacement options.
WARNING, DANGER
Ensure the device always has adequate ventilation; do not block the
vents or obstruct airow at the back or sides of the unit.
The earth conductor must be correctly installed and reliably connected.
Do not touch the system with wet hands.
Do not wipe the system with a damp cloth.
Regulatory Information
This product complies with the applicable EU and UK directives/regulations:
Radio Equipment (RED Directive 2014/53/EU & SI 2017 No. 1206
Low Voltage (LVD Directive 2014/35/EU & SI 2016 No. 1101)
Electromagnetic Compatibility (EMC Directive 2014/30/EU & SI 2016
No. 1091)
A copy of the Declaration of Conformity is available through the myenergi
support portal.
https://support.myenergi.com/hc/en-gb/categories/20493987114129-
Compliance-Download-Centre
Radio Equipment (RED)
This device incorporates a 868/915MHz radio and 2.4GHz wireless
transmitter, and complies with EN62311 for risks to human exposure.
Radio operates in bands between 868–870MHz / 915–916.3MHz – 25mW
max.
WiFi operates between 2412-2484 MHz (802.11 b/g/n) - 100mW max.
Electromagnetic Compatibility (EMC)
This device has been designed and tested to full applicable standards for:
Radio frequency emissions when installed according to the instructions
and used in its intended environment.
Immunity to electrical and electromagnetic phenomena when installed
according to the instructions and used in its intended environment.
This device generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with this instruction manual, may cause
harmful interference to radio communications. Modications not expressly
approved by the manufacturer could void the user’s authority to operate the
equipment under EU rules.
Electrical Safety
This device is a Class 1 electrical item in accordance with EN 60730-1.
Installation shall be ≤ 2000m above sea level.
The supply for single-phase devices shall have a voltage of 230V AC ±
10%.
The supply for three-phase devices shall have a voltage of 230/400V
AC ± 10%.
This device must be supplied by an upstream 3-pole 16A type A or B
MCB or equivalent overcurrent device.
The cross sectional area of the supply conductors shall be between
2.5mm² and 4mm² (stranded/solid) and rated at 500V min. Torque
0.5Nm. Wiring shall be installed without stress and free from being
scratched by sharp objects.
G100 Compliance
eddi+ supports the Customer Import and Export Limitation Scheme
(CLS), in accordance with G100 issue 2. Where G100 is required as part of
an installation, then the installer must adhere to the G100 Commissioning
Guidance document which can be located here:
https://support.myenergi.com/hc/en-gb/categories/20493987114129-
Compliance-Download-Centre
Once the CLS is setup correctly, the master device within the myenergi
eco-system will monitor the maximum import and export, and if necessary,
instruct other devices to increase or decrease import or export if these
maximum thresholds are ever exceeded.
Disposal
In accordance with European Directive 2012/19/EU on waste electrical and
electronic equipment and its implementation in national law, used electrical
devices must be collected separately and recycled in an environmentally
responsible manner. Ensure that you return your used device to myenergi
or obtain information regarding a local, authorised collection and disposal
system. Failure to comply with this EU Directive may result in a negative
impact on the environment.
EN
02/16

Related product manuals