EasyManua.ls Logo

Myenergi Eddi+ - Appendix A: Application Examples

Myenergi Eddi+
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A: Application Examples
1. eddi+ tted to a single cylinder with a single phase immersion heater.
Date
Drawn
Auth
Drawing Number
Title
Description
RevisionStatus
eddi+, Single Cylinder, Single Phase Heater
June 24
API
JC
ED3P0200001
DRAFT R04
eddi+ fitted to a single cylinder, with a single phase
immersion heater
3
4
6
Key
1. eddi+ three phase Solar Power Diverter
2. 230/400V AC power supply
3. Hot Water Storage Tank
4. Single phase immersion heater
5. 3kW Immersion heater
6. Auxilary Gas Boiler
7. Supplied PT1000 temperature sensor
7
N
Immersion heater
5
Over Temp
cut-out
Control
Thermostat
N
L1
L2
L3
230/400V AC
2
RELAY 1
OUTPUT
LOAD
POWER
SUPPLY
eSENSE
CT
INPUT
PT 1000
INPUT
RELAY 2
NO C NC
24V
OUT
24V OUT
24-230V
AC/DC IN
24-230V
AC/DC IN
C
NO C NC
H3 H2 H1 NL1L1 L2 L3N N
1
Date
Drawn
Auth
Drawing Number
Title
Description
RevisionStatus
eddi+, Single Cylinder, Single Phase Heater
June 24
API
JC
ED3P0200001
DRAFT R04
eddi+ fitted to a single cylinder, with a single phase
immersion heater
3
4
6
Key
1. eddi+ three phase Solar Power Diverter
2. 230/400V AC power supply
3. Hot Water Storage Tank
4. Single phase immersion heater
5. 3kW Immersion heater
6. Auxilary Gas Boiler
7. Supplied PT1000 temperature sensor
7
N
Immersion heater
5
Over Temp
cut-out
Control
Thermostat
N
L1
L2
L3
230/400V AC
2
RELAY 1
OUTPUT
LOAD
POWER
SUPPLY
eSENSE
CT
INPUT
PT 1000
INPUT
RELAY 2
NO C NC
24V
OUT
24V OUT
24-230V
AC/DC IN
24-230V
AC/DC IN
C
NO C NC
H3 H2 H1 NL1L1 L2 L3N N
1
06/16