Root device
Note: the EndPoint01 mirrors equivalent effect root endpoint.
Support command class Support S2/s0
COMMAND_CLASS_ZWAVEPLUS_INFO
V2
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_SECURITY_2 V1
COMMAND_CLASS_SUPERVISION V1
COMMAND_CLASS_SENSOR_MULTILEVEL V5
YES
YES
V2
YESV3
YESV1
YESV3
YESV1
YESV2
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
OMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_THERMOSTAT_MODE
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
COMMAND_CLASS_THERMOSTAT_SETPOINT
EndPoint1 command list:
Support command class Support S2/S0
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
V2
V1
V1
V1
V5
YES
YES
V2
YES
V3
YESV1
EndPoint2 (floor temperature sensor) command list:
Group ID Description
1 5
NAME
Lifeline
Profile Max nodes
AGI_LIFE_LINE
0x0001
1.Send Command Class
DEVICE_RESET_LOCALLY_NOTIFICATION to associated
devices of this group when factory reset the device.
2.Send Command Class
THERMOSTAT_SETPOINT_REPORT,
THERMOSTAT_MODE_REPORT,
THERMOSTAT_OPERATING_STATE_REPORT to associated
devices of this group When operation mode and
temperature change.
3.Send Command Class NOTIFICATION_REPORT to
associated devices of this group when over current, over
heat detected
4.Send Command Class METER_REPORT to associated
devices of this group to report metering parameters.
5.Association
2 5Heat Set
AGI_CONTROL_
KEY01
(0x2001)
Transfer Command Class THERMOSTAT_SETPOINT_SET
THERMOSTAT_MODE_SET
to control other temperature control devices when
operation changes