0x0E(14) 21
Dry Mode
Schedule
Set the mode a fter the drying mode ends
0x00 = OFF
0x01 = Manual mode (comfort mode)
0x02 = Auto mode (energy save mode)
0x03 = Away mode
0x10(16) 21 None
When to report temperature relative change threshold value actively, unit
is 0.1℃
0, d isab l e t o r ep or t
2- 10, rep or t when t he threshold v alue i s 2- 10
Note: the EndPoint01 has equivalent effect of root function.
EndPoint02
Group ID Description
1 0
NAME
Lifeline
Profile Max nodes
AGI_LIFE_LINE
(0x0001)
Lifeline(0x0001)
Group ID Description
1 0
NAME
Lifeline
Profile Max nodes
AGI_LIFE_LINE
(0x0001)
Lifeline(0x0001)
Parameter
Parent
Menu
0x02(2) 16
Size
1
Description
Default
Value
Monitor Set
6.Advance Config Parameters
Over current detection max. value, unit is A. When detected current is
over this
value, the device will turn off the relay and send NOTIFICATION CC.
0, disable over current detection
5-16, over current detection max. value
0x03(03) 11 Other Set
Vibration level and buzzer level triggered by pressing buttons 0, disable
vibration and buzzer
1, Low Level
2, High Level
0x0A(10) 11 Other Set
Temperature control reference selection
1, room sensor
2, floor sensor
3, room+floor sensor
0x04(4) 11 Other Set
Whether to recover to settings before power failure or power reset
0, use default settings
1, recover to settings before power failure or power reset
0x08(8) 01 None
Auto mode (Energy save mode) temperature schedule
0, use schedule set by user
1, use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET
0x06(6) 451 Monitor Set
High temperature detection max. value, unit is ℃ , when either
temperature sensor is higher than this value, the device will turn off the
relay and send NOTIFICATION CC.
0, disable this function
20-60, the high temperature value
0x09(9) 11 Other Set
Select floor temperature sensor type
1, NTC/10K B(25/50°C)=3950
2, NTC/15K B(25/50°C)=3950
3, NTC/50K B(25/50°C)=3950
4, NTC/100K B(25/50°C)=3950
0x07(7) 51 Monitor Set
Temperature control hysteresis value setting, setting range 0.5℃- 2℃
5-20, unit is 0.1℃
0x0B(11) 01 Other Set
ROOM SENSOR temperature compensation setting
-10~10, unit is 0.5℃
0x0C(12) 01 Other Set
FLOOR S ENSOR temperature compensation setting
-10~10, unit is 0.5℃
0x0D(13) 301
Dry Mode
Schedule
Set how long the drying mode lasts
5~100, unit is minute
EndPoint01 :