D3
heatless desiccant air dryer
3. Remove the screw from the sensor plug (Figure D.2) and detach it from the dew point sensor assembly. (See Figure D.2.1)
4. Unscrew the dew point sensor from the sensor block and replace with the new or
re-calibrated sensor making sure the mating surfaces are clean. (See Figure D.3.2)
5. Reattach the new or re-calibrated dew point sensor and sensor block assembly to
the controller chassis plate using the 2x xing screws.
6. Replace the sensor plug and screw to complete the sensor assembly.
7. Close the shroud and ensure the latches are in position.
8. Start up the Dryer (page 8)
9. Allow for sensor ‘bedding in’ time.