WI879A GEM-P400 Installation Instructions
Arming/Disarming with a Keyfob
The system can be armed by pressing the
key, and disarmed by pressing the
key on
the Keyfob. Zones programmed as
Exit/Entry
Follower Zones
can be bypassed when the
or
keys on the Keyfob have been pro-
grammed for
Interior
[81-82]. Zones pro-
grammed as Home
/Away with Delay Zones
can
be armed regardless of the state of the
Exit/Entry
Zones
when the
or
keys on the Keyfob
have been programmed for
Full Set
[81-82]. To
arm the system with all zones protected press
the
key. Press and hold the
or
key for 1.5s to fully set the system (The LED on
the Keyfob indicate the Keyfob has transmitted
the signal). Program
Keyfob/Keyswitch Chirp
[23-4] for an audible indication of system arming
and disarming.
Arming Instant with a Keyfob
The panel can be ARMED INSTANT when the
or
keys on the Keyfob have been
programmed for
Instant
[81-82]. To arm the
system with Instant protection press the
key, then press and hold the
or
key for
1.5s to arm the panel with INSTANT protection.
Arming/Disarming with a Keyswitch
The system can be armed/disarmed by using a
momentary Keyswitch wired to Zone 4. Pro-
gram Keyfob/Keyswitch Chirp [23-4] for an au-
dible indication of system arming and disarm-
ing.
Disarming (System OFF)
After entering the premises through an Exit/
Entry Zone, the keypad will sound the Entry
Delay Tone. Enter a valid Arm/Disarm code,
then press
. If a valid Arm/Disarm code is
entered, the keypad will beep 6 times, indicat-
ing the panel has been disarmed. The red
Armed LED will go out. If an incorrect Arm/
Disarm Code is entered, the keypad will sound
a 1-second tone, indicating incorrect entry.
Press the
key and re-enter the code.
Disarming after an Alarm
(Alarm Memory)
The armed LED and the zone(s) that caused
the alarm will be be flashing. Disarm the panel.
The system is currently not detecting zone
faults or displaying system trouble. The
zone(s) that caused the alarm will continue to
flash. The Ready and
SYSTEM TRBL LEDs
are out indicating:
The system is displaying
Alarm Memory
.
Press the
key to clear Alarm Memory.
%\SDVVLQJ
Automatic Bypassing
Home/Away with Delay Zones
This zone type has the following operation de-
pending on whether an
Exit/Entry Zone
has been
violated during the
Exit Delay
time.
Home
Exit/Entry Zone
is not violated
Zones selected as Home/Away with Delay
Zones
will be bypassed automatically.
Away with Delay
E xit/Entry Zone is violated
Zones selected as Home/Away with Delay
Zones
will have a fixed 20-second entry de-
lay when violated before an
Exit/Entry Zone
.
N
OTE
:
Faulted Keyswitch or silent 24 hour zones normally do not
display at the keypad. If a silent 24 hour zone or
Keyswitch is faulted at the time of arming the faulted zone
will display only while the priority sound is ON.
Wi879a
page 8
Tuesday, September 16, 1997 08:16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P400 and is the answer not in the manual?

NAPCO Gemini GEM-P400 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P400
CategoryControl Panel
LanguageEnglish

Related product manuals