NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 2
NAPCO Security Group
Programming Instructions, Volume 2 Page 77
AREA SYSTEM TROUBLE REPORTING OPTIONS (A DDRESS 1890-1927)
1. Select the desired option entering the option number (1-8) for each digit.
2. Enter corresponding option number in address location.
NOTE: Dark shaded data value box shows option not available.
3. Press U to save.
SYSTEM RESPONSE
ACTIVATED BY AREA 2
EVENT/TROUBLE
AREA 2 SYSTEM EVENT/TROUBLE
ADDR
AMBUSH
KEYPAD
PANIC
KEYPAD
FIRE
KEYPAD
AUX.*
KEYPAD
TAMPER
FAIL TO
OPEN
FAIL TO
CLOSE
RSRVD.
1 2 3 4 5 6 7 8
Pulsed Burg. Bell
1900
Burglary Bell
1901
Default ON
Default ON
Burg PGM2
1902
Burg Relay
1903
Burg PGM1
1904
Report Alarm Telco 1
1905
Default ON Default ON
Report Alarm Telco 3
1907
[Defaults as noted from address 1900-1907] * NOTE: Keypad Aux. is not to be selected for UL Installations.
SYSTEM RESPONSE
ACTIVATED BY AREA 3
EVENT/TROUBLE
AREA 3 SYSTEM EVENT/TROUBLE
ADDR
AMBUSH
KEYPAD
PANIC
KEYPAD
FIRE
KEYPAD
AUX.*
KEYPAD
TAMPER
FAIL TO
OPEN
FAIL TO
CLOSE
RSRVD.
1 2 3 4 5 6 7 8
Pulsed Burg. Bell
1910
Burglary Bell
1911
Burg PGM2
1912
Burg Relay
1913
Burg PGM1
1914
Report Alarm Telco 1
1915
Report Alarm Telco 3
1917
[Default = blank (•) blank (•) from address 1910-1917] * NOTE: Keypad Aux. is not to be selected for UL Installations.
SYSTEM RESPONSE
ACTIVATED BY AREA 4
EVENT/TROUBLE
AREA 4 SYSTEM EVENT/TROUBLE
ADDR
AMBUSH
KEYPAD
PANIC
KEYPAD
FIRE
KEYPAD
AUX.*
KEYPAD
TAMPER
FAIL TO
OPEN
FAIL TO
CLOSE
RSRVD.
1 2 3 4 5 6 7 8
Pulsed Burg. Bell
1920
Burglary Bell
1921
Burg PGM2
1922
Burg Relay
1923
Burg PGM1
1924
Report Alarm Telco 1
1925
Report Alarm Telco 3
1927
[Default = blank (•) blank (•) from address 1920-1927] * NOTE: Keypad Aux. is not to be selected for UL Installations.

Other manuals for NAPCO GEMINI GEMC-128

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO GEMINI GEMC-128 and is the answer not in the manual?

NAPCO GEMINI GEMC-128 Specifications

General IconGeneral
BrandNAPCO
ModelGEMINI GEMC-128
CategoryControl Panel
LanguageEnglish

Related product manuals