NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 2
NAPCO Security Group
Programming Instructions, Volume 2 Page 91
DEFAULTS
The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
• Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown , Zone Area 1 and Zone Area 2 are enabled for
the total number of zones entered in "AREA 1 # ZONES = 08" and "AREA 2 # ZONES = 00".
• Alarm Telco 1 is enabled for the zones if [YES] is entered for "REPORT ALL ZONES TO CENTRAL ZONES? Y/N".
• Entry/Exit 1 and Chime are enabled for zone numbers entered in "EXIT / ENTRY ZONES".
• Exit/Entry Follower and Interior Bypass are enabled for zone numbers entered in "INTERIOR ZONES".
• Fire, Pulse Alarm Output and Fire Verification is enabled for the zone numbers entered in "FIRE ZONES".
Note: See "Number of Zones & Keypads per Area" in Easy Menu Driven program Mode.
ZONE OPTIONS / ZONES 1-96 (ADDRESS 2002-3188)