Page #9 background imageLoading...
Page #9 background image
9
W415-0210 / R / 02.27.08
VENTING APPLICATION FLOW CHART
FIREPLACE VENT EXIT
REAR EXIT
TOP EXIT
Horizontal Termination
Vertical Termination
Vertical Termination
Vertical rise
is equal to
or greater
than the
horizontal
run
Vertical rise
is less than
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
Horizontal
run + verti-
cal rise to
maximum of
24.75 feet
3.5 times the
vertical rise
equal to or
greater than
the horizon-
tal run
Horizontal Termination
Vertical rise
is equal to
or greater
than the
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
Vertical rise
is equal to
or greater
than the
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
Vertical rise
is equal to
or greater
than the
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
Vertical rise
is less than
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
3 times the
vertical rise
equal to or
greater than
the horizon-
tal run
Vertical rise
is less than
horizontal
run
Horizontal
run + verti-
cal rise to
maximum of
24.75 feet
4.2 times the
vertical rise
equal to or
greater than
the horizon-
tal run
Vertical rise
is less than
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
3 times the
vertical rise
equal to or
greater than
the horizon-
tal run
NorthlineExpress.com
http://www.northlineexpress.com
Toll-Free 1-866-667-8454

Other manuals for Napoleon BGD36PTR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon BGD36PTR and is the answer not in the manual?

Napoleon BGD36PTR Specifications

General IconGeneral
BrandNapoleon
ModelBGD36PTR
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals