1
W415-0297 / P / 02.03.12
SAFETY INFORMATION
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
- This is an unvented gas- red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided. Refer to
section “ COMBUSTION AND VENTILATION AIR
PROVISIONS”.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
1.23B
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com • ask@napoleonproducts.com
!
WARNING
If the information in these instructions are
not followed exactly, a re or explosion
may result causing property damage,
personal injury or loss of life.
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.
$10.00
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
GVF36P
PROPANE
GVF36N
NATURAL GAS
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2, VOLUME II FOR UNVENTED ROOM HEATERS.
UNVENTED MILLIVOLT
SYSTEM

Other manuals for Napoleon GVF36N

Questions and Answers

  • S
    Scott MartinezSep 3, 2025
    Why is there no spark at the pilot burner on my Napoleon Gas Heater?
    • E
      Elizabeth HarrisonSep 3, 2025
      If you're not getting a spark at the pilot burner of your Napoleon Gas Heater, check that the wire is connected to the push button ignitor and that the push button ignitor is tightened. If the wire insulation is broken or frayed, replace the wire. If the ceramic insulator on the electrode is cracked or broken, replace the electrode. If problems persist, replace the push button ignitor.
  • C
    Christine RamirezSep 18, 2025
    Why does the pilot light go out when I release the gas knob on my Napoleon GVF36N Indoor Fireplace?
    • C
      carolbrownSep 18, 2025
      If the pilot light goes out when you release the gas knob on your Napoleon Indoor Fireplace, it's likely because the gas valve has an interlock device. This device prevents the pilot burner from lighting until the thermocouple has cooled down. To resolve this, allow approximately 60 seconds for the thermocouple to cool before attempting to light the pilot again.
  • E
    Elizabeth PerezSep 14, 2025
    What to do if wall switch is mounted upside down on my Napoleon Gas Heater?
    • B
      Brandon GeorgeSep 14, 2025
      If the wall switch is mounted upside down on your Napoleon Gas Heater, reverse it.
  • J
    Jose DeleonSep 12, 2025
    What to do if air shutter is blocked on my Napoleon Gas Heater?
    • G
      George MartinezSep 12, 2025
      If the air shutter on your Napoleon Gas Heater has become blocked, ensure the air shutter opening is free of lint or other obstructions.
  • J
    Jessica SimpsonSep 12, 2025
    What to do if my Napoleon Gas Heater is out of propane gas?
    • C
      Cheryl WilliamsSep 12, 2025
      If your Napoleon Gas Heater is out of propane gas, fill the tank.
  • L
    Laurie EllisSep 9, 2025
    What to do if wall switch wiring is defective on my Napoleon Gas Heater?
    • L
      Larry SinghSep 9, 2025
      If the wall switch wiring is defective in your Napoleon Gas Heater, disconnect the wires from the valve. Connect a jumper wire across terminals 1 & 3; if the main burner lights, check the wires for defects and/or replace the wires.
  • P
    Patricia AguirreSep 7, 2025
    What to do if my Napoleon Gas Heater is over-fired or under-fired?
    • S
      Steven WadeSep 8, 2025
      If your Napoleon Gas Heater is over-fired or under-fired, check the inlet and outlet pressure readings. The inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Check with burner operating on 'HI'. The gauge should read 7” (minimum 4.5”) water column for natural gas or 13” (11” minimum) water column for propane. The outlet pressure can be checked the same as above using screw (B). Check with burner operating on 'HI'. Gauge should read 3.5” water column for natural gas or 10” water column for propane. After taking pressure readings, be sure to turn screws clockwise firmly to reseal. Do not over torque. Leak test with a soap and water solution.
  • J
    Jeffery HallSep 6, 2025
    What to do if thermopile shorting on Napoleon Gas Heater?
    • S
      Shawn WatersSep 6, 2025
      If the thermopile in your Napoleon Gas Heater is shorting or has a loose connection, clean the thermopile connection to the valve, reconnect any loose connections, or replace the thermopile or valve.
  • L
    Leslie DuncanSep 4, 2025
    What to do if pilot goes out when the gas knob is released on my Napoleon Gas Heater?
    • J
      Jose HillSep 4, 2025
      If the pilot light goes out when you release the gas knob on your Napoleon Gas Heater, allow a few seconds for the thermocouple to cool.
  • C
    christopher83Aug 21, 2025
    How to fix a pilot flame that is not large enough on my Napoleon Gas Heater?
    • M
      Marcia HansonAug 21, 2025
      If your Napoleon Gas Heater's pilot flame isn't large enough, it might be due to low supply pressure. You can service or replace the Oxygen Depletion Sensor System, ensure correct piping and/or regulator to provide correct pressure, or ensure adequate supply pressure.

Napoleon GVF36N Specifications

General IconGeneral
Ignition TypeElectronic Ignition
Log MaterialCeramic Fiber
Fuel TypeNatural Gas
Heat Output36, 000 BTU
Viewing Area36"
BTU36, 000 BTU/h