EasyManua.ls Logo

Napoleon GDI-44N - User Manual

Napoleon GDI-44N
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
W415-0734 / D / 02.03.12
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleon replaces.com • ask@napoleonproducts.com
1.28C
$10.00
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
GDI-44N
NATURAL GAS
GDI-44P
PROPANE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.50 FOR VENTED GAS FIREPLACE.

Other manuals for Napoleon GDI-44N

Questions and Answers

  • M
    Mary GregoryAug 12, 2025
    What to do if I smell exhaust fumes and have headaches from my Napoleon Indoor Fireplace?
    • B
      Brittany BlanchardAug 13, 2025
      If you smell exhaust fumes in the room and are experiencing headaches, it's likely that the room is in negative pressure. You should increase the fresh air supply to the room.
  • G
    gjonesAug 16, 2025
    What to do if my Napoleon GDI-44N is out of propane gas?
    • J
      Jennifer HarrisAug 17, 2025
      If your Napoleon Indoor Fireplace is out of propane gas, the solution is to fill the tank.
  • K
    keithwilliamsAug 20, 2025
    Why won't the pilot light on my Napoleon GDI-44N Indoor Fireplace, and there's no spark?
    • M
      Michelle SalasAug 20, 2025
      If the pilot on your Napoleon Indoor Fireplace won't light and there's no spark at the pilot burner, try these steps: 1. Check if the pilot can be lit by a match. 2. Check that the wire is connected to the push button igniter. 3. Check if the push button igniter needs tightening.
  • J
    Jamie WilliamsAug 25, 2025
    What to do if there's no gas at the pilot burner of my Napoleon GDI-44N Indoor Fireplace?
    • M
      Matthew Mathis Jr.Aug 25, 2025
      If there's no gas at the pilot burner of your Napoleon Indoor Fireplace, check that the manual valve is turned on and check the pilot orifice for blockage.
  • R
    Robert Berger MDAug 27, 2025
    What is the correct spark gap for a Napoleon Indoor Fireplace?
    • P
      Paul WarrenAug 27, 2025
      The spark gap should be 0.150” to 0.175” (approximately 5/32” to 11/64”) from the electrode tip and the pilot burner. To ensure proper electrode location, tighten the securing nut (finger tight plus 1/4 turn).
  • U
    ufarrellAug 31, 2025
    What to do if the pilot flame isn't large enough on my Napoleon Indoor Fireplace?
    • J
      Jennifer BlackwellAug 31, 2025
      If the pilot flame on your Napoleon Indoor Fireplace is not large enough or not engulfing the thermocouple, turn up the pilot flame.
  • K
    Karen BruceSep 4, 2025
    Why does the pilot light go out while standing, even when the main burner is off on my Napoleon GDI-44N?
    • G
      Gregory WalkerSep 4, 2025
      If the pilot goes out while standing and the main burner is in the ‘OFF’ position, connect a jumper wire across the wall switch terminals. If the main burner lights, replace the switch or thermostat.
  • K
    Kelly DillonSep 8, 2025
    What to do if both the main burner and pilot light go out on my Napoleon Indoor Fireplace?
    • C
      Cameron GrossSep 8, 2025
      The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool before attempting to relight the pilot on your Napoleon Indoor Fireplace.

Summary

Safety Information

Installation Overview

General Instructions

Installation

Chimney Connection

Details how to connect the appliance to the chimney using liners and appropriate kits.

Gas Installation

Guidance on connecting the gas supply, ensuring safety and compliance with codes.

Replacement Blower Installation

Operation

Lighting Instructions

Step-by-step guide for lighting the pilot and main burners safely.

To Turn Off Gas

Procedure for safely shutting off the gas supply to the appliance.

Operating Instructions

General safety and operational guidelines for using the fireplace.

Adjustments

Maintenance

Door Glass Replacement

Instructions for safely replacing the appliance's door glass.

Replacements

Trouble Shooting

Warranty

Napoleon GDI-44N Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
BTU40, 000
Efficiency85%
Vent TypeDirect Vent
Ignition TypeElectronic Ignition
Log MaterialCeramic Fiber
TypeInsert
Fuel Type OptionNatural Gas or Propane