What to do if faulty valve in Napoleon Madison GD80NT?
- VvmillerSep 23, 2025
If the valve is faulty, the only suggested solution is to replace it.
What to do if faulty valve in Napoleon Madison GD80NT?
If the valve is faulty, the only suggested solution is to replace it.
Why flame is impinging on the logs or combustion chamber in Napoleon Indoor Fireplace?
If the flame is hitting the logs or combustion chamber, make sure the logs are in the right spot. Try opening the air shutter to let more air in. Check the input rate by looking at the manifold pressure and orifice size, matching them to what's on the rating plate. Make sure the door's seal isn't broken or missing and that it's tight. Check that both vent liners don't have holes and are sealed well at all joints. Also, make sure any horizontal venting has the right rise per foot.
Why does white / grey film forms on Napoleon Madison GD80NT Indoor Fireplace?
If you see a white or grey film forming, it's likely sulphur from the fuel depositing on the glass, logs, or combustion chamber. Clean the glass with a gas fireplace glass cleaner that's recommended. Remember, don't clean the glass when it's hot. If you don't clean the deposits regularly, the glass might get permanently marked.
What to do if main burner goes out; pilot stays on in Napoleon Indoor Fireplace?
If the main burner goes out but the pilot light stays on, try turning up the pilot flame. If that doesn't work, you might need to replace the pilot assembly.
How to fix thermopile shorting in Napoleon Madison GD80NT Indoor Fireplace?
To address a thermopile shorting issue, try cleaning the thermopile connection to the valve and then reconnect it. If the problem continues, consider replacing the thermopile or the valve.
What to do if remote wall switch wire is grounding in Napoleon Madison GD80NT?
If the remote wall switch wire is grounding, check for a short and repair the ground or replace the wire.
What to do if wall switch is mounted upside down in Napoleon Madison GD80NT Indoor Fireplace?
If the wall switch is mounted upside down, reverse it.
What to do if remote wall switch is grounding in Napoleon Indoor Fireplace?
If the remote wall switch is grounding, replace it.
How to fix thermocouple shorting / faulty in Napoleon Madison GD80NT?
If experiencing issues with the thermocouple, try loosening and tightening it. Also, clean the thermocouple and valve connection. If problems persist, replacement of the thermocouple or valve may be necessary.
Why remote wall switch wire is too long; too much resistance in the Napoleon Indoor Fireplace system?
If the remote wall switch wire is too long, causing too much resistance, shorten the wire to the correct length or use a different wire gauge.