SAFETY INFORMATION
!
WARNING
If the information in these instructions are
not followed exactly, a re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
GD80NT
NATURAL GAS
GD80PT
PROPANE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.

Table of Contents

Questions and Answers

  • O
    Oscar DavisSep 23, 2025
    What to do if faulty valve in Napoleon Indoor Fireplace?
    • S
      sharprussellSep 23, 2025
      If the valve is faulty, the only suggested solution is to replace it.
  • R
    Reginald FisherAug 23, 2025
    Why flame is impinging on the logs or combustion chamber in Napoleon Madison GD80PT?
    • R
      Robert GreenAug 25, 2025
      If the flame is hitting the logs or combustion chamber, make sure the logs are in the right spot. Try opening the air shutter to let more air in. Check the input rate by looking at the manifold pressure and orifice size, matching them to what's on the rating plate. Make sure the door's seal isn't broken or missing and that it's tight. Check that both vent liners don't have holes and are sealed well at all joints. Also, make sure any horizontal venting has the right rise per foot.
  • L
    Linda JenningsAug 25, 2025
    Why does white / grey film forms on Napoleon Madison GD80PT?
    • P
      Paige GarciaAug 26, 2025
      If you see a white or grey film forming, it's likely sulphur from the fuel depositing on the glass, logs, or combustion chamber. Clean the glass with a gas fireplace glass cleaner that's recommended. Remember, don't clean the glass when it's hot. If you don't clean the deposits regularly, the glass might get permanently marked.
  • S
    scott76Aug 27, 2025
    What to do if main burner goes out; pilot stays on in Napoleon Indoor Fireplace?
    • J
      Joe BellAug 27, 2025
      If the main burner goes out but the pilot light stays on, try turning up the pilot flame. If that doesn't work, you might need to replace the pilot assembly.
  • M
    mckinneykevinAug 28, 2025
    How to fix thermopile shorting in Napoleon Madison GD80PT Indoor Fireplace?
    • S
      sarah10Aug 28, 2025
      To address a thermopile shorting issue, try cleaning the thermopile connection to the valve and then reconnect it. If the problem continues, consider replacing the thermopile or the valve.
  • K
    Katherine ThompsonSep 18, 2025
    What to do if remote wall switch wire is grounding in Napoleon Indoor Fireplace?
    • D
      Debra HansonSep 18, 2025
      If the remote wall switch wire is grounding, check for a short and repair the ground or replace the wire.
  • P
    Paul DavisSep 15, 2025
    What to do if wall switch is mounted upside down in Napoleon Madison GD80PT?
    • N
      Natalie EvansSep 15, 2025
      If the wall switch is mounted upside down, reverse it.
  • L
    Luke SmithSep 16, 2025
    What to do if remote wall switch is grounding in Napoleon Madison GD80PT?
    • M
      Mary CannonSep 17, 2025
      If the remote wall switch is grounding, replace it.
  • C
    Cheryl WaltonSep 6, 2025
    How to fix thermocouple shorting / faulty in Napoleon Madison GD80PT?
    • D
      David WilliamsSep 6, 2025
      If experiencing issues with the thermocouple, try loosening and tightening it. Also, clean the thermocouple and valve connection. If problems persist, replacement of the thermocouple or valve may be necessary.
  • T
    Teresa AndradeSep 3, 2025
    Why remote wall switch wire is too long; too much resistance in the Napoleon Madison GD80PT system?
    • E
      Eric HillSep 4, 2025
      If the remote wall switch wire is too long, causing too much resistance, shorten the wire to the correct length or use a different wire gauge.

Summary

Introduction to Napoleon Fireplace

Appliance Dimensions and General Instructions

Appliance Dimensions

Details the physical measurements and diagrams of the appliance.

General Installation Instructions

Key safety precautions and general installation guidelines for the appliance.

General Information and Rating Plate

General Appliance Information

Covers installation codes, certifications, and key appliance specifications.

Rating Plate Information

Explains how to interpret the appliance's rating plate for proper identification.

Venting System Guide

Venting Lengths and Components

Lists approved vent parts, suppliers, and guidelines for vent system configuration.

Typical Vent Installation

Illustrates standard methods for installing the appliance's venting system.

Special Vent Installation

Covers specific venting configurations, including periscope terminations.

Periscope Termination

Instructions for using a periscope kit for air termination above grade.

Minimum Air Terminal Clearances

Venting Calculations and Definitions

Venting Application Flow Chart

Flowchart for determining correct vent configurations based on rise and run.

Venting Definitions

Defines key terms and symbols used in venting calculations.

Horizontal and Vertical Termination Guidelines

Top Exit Horizontal Termination

Guidance and formulas for calculating vent lengths and rise for horizontal terminations.

Vertical Termination

Formulas and guidance for calculating vent lengths and rise for vertical terminations.

Installation Procedures

Installation Overview

General warnings and instructions for the installation process.

Wall and Ceiling Protection

Guidance on protecting walls and ceilings from heat and ensuring proper clearances.

Horizontal Vent Installation

Steps for installing the vent terminal through an exterior wall.

Vertical Vent Installation

Steps for installing the vent terminal through a roof.

Flexible Vent Components and Connections

Using Flexible Vent Components

Instructions for using flexible vent pipes and ensuring proper installation.

Horizontal Air Terminal Installation

Detailed steps for connecting a flexible vent to a horizontal air terminal.

Vertical Air Terminal Installation

Detailed steps for connecting a flexible vent to a vertical air terminal.

Appliance Vent Connection

Instructions for connecting the vent pipe assembly to the appliance.

Mobile Home and Gas Installation

Mobile Home Installation

Specific installation requirements for mobile and manufactured homes.

Gas Installation

Critical safety warnings and procedures for connecting the gas supply.

Framing and Clearance Requirements

Framing the Appliance

Instructions and warnings related to building the appliance enclosure and framing.

Minimum Clearance to Combustibles

Specifies minimum clearances required between the appliance and combustible materials.

Minimum Clearance to Combustible Enclosures

Details clearances required for the appliance enclosure using non-combustible materials.

Minimum Mantel Clearances

Guidance and a graph for determining safe mantel clearances above the appliance.

Finishing and Log Placement

Finishing the Appliance

Safety warnings and guidelines for finishing the appliance exterior.

Door Removal and Installation

Step-by-step instructions for safely removing and installing the appliance door.

Log Shipping Bracket Removal

Instructions for removing the log shipping bracket before log installation.

Decorative Brick Panel Installation

Detailed steps for installing the decorative interior brick panels.

Log Placement

Appliance Operation

General Transmitter Layout

Diagram and explanation of the components and display of the remote transmitter.

Appliance Operation Steps

Step-by-step guide for initial setup and operation of the appliance via remote.

Hand Held Remote Operations

Explanation of how to use the remote control for basic functions like ON/OFF.

Temperature Display Settings

How to change and verify the temperature display units (Fahrenheit/Celsius).

Remote Control Features

Room Thermostat Function

Instructions on using the remote transmitter as a room thermostat.

Smart Thermostat Function

Details on the Smart Thermostat function that adjusts flame based on room temperature.

Flame Height Adjustment

How to adjust the flame level using the remote control buttons.

Fan Speed Control

Instructions for controlling the fan speed using the remote control.

Advanced Operation and Safety

Child Proof Function

Procedure to lock and unlock the remote control keys for safety.

Night Light Control

How to control the appliance's auxiliary outlet for the Night Light feature.

Low Battery and Manual Bypass

Information regarding battery status and manual operation modes.

Power Failure Operation

How the fireplace functions and is controlled during a power outage.

Electrical Information and Operation

Electrical Information

Critical warnings and compliance requirements for electrical installation.

Hard Wiring Connection

Detailed instructions and diagrams for hardwiring the appliance's electrical connections.

Operating Instructions

General safety, lighting, and shutdown procedures for operating the fireplace.

What to Do If You Smell Gas

Emergency procedures to follow in case of a gas leak.

Appliance Adjustments

Pilot Burner Adjustment

Instructions for adjusting the pilot flame size and checking gas pressures.

Venturi Adjustment

Guidance on adjusting the air shutter for optimal flame characteristics.

Flame Characteristics

Visual checks and comparison of pilot and burner flames for proper operation.

Air Control Rod Access

Steps to access and adjust the air control rod for the combustion chamber.

Maintenance Procedures

Appliance Maintenance

Important warnings and general procedures for maintaining the appliance.

Inner Access Panel Access

Instructions for accessing the appliance's control area via the inner access panel.

Night Light Replacement

Procedure for replacing the lamp and lens for the Night Light feature.

Blower Replacement

Step-by-step guide for replacing the appliance's heat circulating blower.

Component Removal and Care

Remote Receiver Removal

Instructions for safely removing the remote control receiver unit.

Valve Removal

Procedure for safely removing the gas valve assembly for servicing.

Auto Spark Battery Removal

Instructions for accessing and replacing the battery for the auto-spark module.

Care of Glass

Guidelines for cleaning the appliance's glass, emphasizing safety and proper methods.

Vertical Vent Restriction and Replacements

Restricting Vertical Vents

Method for restricting vertical vents to achieve a more traditional flame appearance.

Replacement Parts

Information on ordering replacement parts, including part numbers and descriptions.

Troubleshooting Guide

Warranty Information

Service History Log

Napoleon Madison GD80PT Specifications

General IconGeneral
TypeGas Fireplace
Fuel TypeNatural Gas or Propane
Ignition SystemElectronic Ignition
Vent TypeDirect Vent
WarrantyLimited Lifetime Warranty
BTU30, 000