4 4
Part Part
22
––
Product IntroductionProduct Introduction
LiFePOLiFePO
44
Battery Battery
Module Module
for for
Telecom Telecom
Operation Operation
ManualManual
Internet data center (IDC)Internet data center (IDC)
Solar energySolar energy
Etc.Etc.
2.52.5
––
Battery Model InstructionBattery Model Instruction
Fig. 2.2Fig. 2.2
––
Instruction of Battery Model for NPFC SeriesInstruction of Battery Model for NPFC Series
2.62.6
––
Electric PerformanceElectric Performance
Table 2.1Table 2.1
––
Battery Model & Electric Performance of NPFC SeriesBattery Model & Electric Performance of NPFC Series
BatteryBattery
ModelModel
RatedRated
VoltageVoltage
(V)(V)
RatedRated
CapacityCapacity
(Ah)(Ah)
VoltageVoltage
Rage (V)Rage (V)
ChargeCharge
Voltage (V)Voltage (V)
Charge Charge
Current Current
(A) (A)
Max.Max.
DischargeDischarge
Current (A)Current (A)
Recomm. Max.Recomm. Max.
48NPFC10 48NPFC10
48 48
10 10
40.5 40.5
to to
54 54
54.0 54.0
2 2
10 10
1010
48NPFC20 48NPFC20
48 48
20 20
40.5 40.5
to to
54 54
54.0 54.0
4 4
20 20
2020
48NPFC30 48NPFC30
48 48
30 30
40.5 40.5
to to
54 54
54.0 54.0
6 6
20 20
2020
48NPFC40 48NPFC40
48 48
40 40
40.5 40.5
to to
54 54
54.0 54.0
8 8
40 40
4040
48NPFC50 48NPFC50
48 48
50 50
40.5 40.5
to to
54 54
54.0 54.0
10 10
40 40
4040
48NPFC60 48NPFC60
48 48
60 60
40.5 40.5
to to
54 54
54.0 54.0
12 12
40 40
4040
48NPFC70 48NPFC70
48 48
70 70
40.5 40.5
to to
54 54
54.0 54.0
14 14
60 60
6060
48NPFC75 48NPFC75
48 48
75 75
40.5 40.5
to to
54 54
54.0 54.0
15 15
60 60
6060
NOTESNOTES
Battery Battery
Model Model
Battery models Battery models
listed in listed in
the the
datasheet are datasheet are
standard products. standard products.
Narada Narada
can can
also also
supplysupply
customized design in cell, BMS and dimensions for various application scenarios.customized design in cell, BMS and dimensions for various application scenarios.
Rated Rated
Voltage Voltage
48V 48V
= =
3.20Vpc * 3.20Vpc *
15pcs 15pcs
(Rated voltage (Rated voltage
of of
each each
LFP cell LFP cell
is is
3.20Vpc)3.20Vpc)
Rated Rated
Capacity Capacity
Five Five
hour hour
rate rate
capacity capacity
(0.2C to (0.2C to
40.5V 40.5V
at at
2525
))

Questions and Answers: