Annex 2Annex 2
––
Instructions Instructions
for for
Dialing Dialing
of of
ADD ADD
1919
LiFePOLiFePO
44
Battery Battery
Module Module
for for
Telecom Telecom
Operation Operation
ManualManual
Annex 2Annex 2
––
Instructions for Dialing of ADDInstructions for Dialing of ADD
ADD is applicable to modules connected in parallel. ADD consists of four binary bits, andADD is applicable to modules connected in parallel. ADD consists of four binary bits, and
maximum quantity of batteries connected in parallel is 16pcs (2^4).maximum quantity of batteries connected in parallel is 16pcs (2^4).
Annexed Table 2.1Annexed Table 2.1
––
Instruction for Addresses of CommunicationInstruction for Addresses of Communication
Instructions for ADD DialingInstructions for ADD Dialing
ModuleModule
No.No.
BinaryBinary
CodeCode
RemarksRemarks
1 2 3 41 2 3 4
OFF OFF
OFF OFF
OFF OFF
OFF OFF
PACK PACK
1 1
0000 0000
Master Master
PACK, PACK,
supports supports
RS232RS232
ONON
OFF OFF
OFF OFF
OFF OFF
PACK PACK
2 2
0001 0001
Slave Slave
PACKPACK
OFFOFF
ONON
OFF OFF
OFF OFF
PACK PACK
3 3
0010 0010
Slave Slave
PACKPACK
ON ONON ON
OFF OFF
OFF OFF
PACK PACK
4 4
0011 0011
Slave Slave
PACKPACK
OFFOFF
ONON
OFF OFF
OFF OFF
PACK PACK
5 5
0100 0100
Slave Slave
PACKPACK
ONON
OFFOFF
ONON
OFF OFF
PACK PACK
6 6
0101 0101
Slave Slave
PACKPACK
OFFOFF
ON ONON ON
OFF OFF
PACK PACK
7 7
0110 0110
Slave Slave
PACKPACK
ON ON ONON ON ON
OFF OFF
PACK PACK
8 8
0111 0111
Slave Slave
PACKPACK
OFF OFF OFFOFF OFF OFF
ONON
PACK PACK
9 9
1000 1000
Slave Slave
PACKPACK
ONON
OFF OFFOFF OFF
ONON
PACK PACK
10 10
1001 1001
Slave Slave
PACKPACK
OFFOFF
ONON
OFFOFF
ONON
PACK PACK
11 11
1010 1010
Slave Slave
PACKPACK
ON ONON ON
OFFOFF
ONON
PACK PACK
12 12
1011 1011
Slave Slave
PACKPACK
OFF OFFOFF OFF
ON ONON ON
PACK PACK
13 13
1100 1100
Slave Slave
PACKPACK
ONON
OFFOFF
ON ONON ON
PACK PACK
14 14
1101 1101
Slave Slave
PACKPACK
OFFOFF
ON ON ONON ON ON
PACK PACK
15 15
1110 1110
SlavSlav
e e
PACKPACK
ON ON ON ONON ON ON ON
PACK PACK
16 16
1111 1111
SlavSlav
e e
PACKPACK
Annexed Table 2.3Annexed Table 2.3
––
Instruction of ADD for Parallel CommunicationInstruction of ADD for Parallel Communication
PACK PACK
1 1
PACK PACK
2 2
PACK PACK
3 3
PACK PACK
4 4
PACK PACK
5 5
PACK PACK
6 6
PACK PACK
7 7
PACK PACK
88
0000 0001 0010 0011 0100 0101 0110 01110000 0001 0010 0011 0100 0101 0110 0111
PACK PACK
9 9
PACK PACK
10 10
PACK PACK
11 11
PACK PACK
12 12
PACK PACK
13 13
PACK PACK
14 14
PACK PACK
15 15
PACK PACK
1616
1000 1001 1010 1011 1100 1101 1110 11111000 1001 1010 1011 1100 1101 1110 1111
NOTE:NOTE:
Counting of ADD shall begin from 0000, without interruption, or parallel communication cannot beCounting of ADD shall begin from 0000, without interruption, or parallel communication cannot be
availableavailable