Other functions of the ON/OFF pushbutton (held down for less than 1 second)
First press, adjustment of pre-selection time. Yellow LED flashes.
Second press, adjustment of switching-on time. Yellow LED is on.
Third press, adjustment of target temperature.
Green LED flashes.
Fourth press, display returns to measured temperature.
2. Adjusting times and temperatures
Adjusted with +/- pushbuttons when the desired function is displayed.
3. Light in sauna room
Light is switched on and off by pressing the pushbutton.
4.2 Signal lights
4. Green light = light on in sauna room
5. Green light = on when measured temperature is displayed.
Flashes when target temperature is displayed.
6. Yellow light = on when switching-on time is displayed.
Flashes when pre-selection time is displayed.
7. Red light = on until target temperature is reached for the first time.
4.3 Error messages
ERR1= a break in the sensor circuit
ERR2= a short-circuit in the sensor
circuit
ERR3= a break in the overheat
protector’s current circuit
NOTE! If an error message
is displayed, switch off
the sauna stove.
5. TECHNICAL DATA
5.1 Upper board
enclosure class IPX4
the control unit can be
installed in the sauna or
in the dressing room
6. LOADING OF STONES
- When loading the stones, make sure they do not bend the resistors or obstruct
sufficient circulation of air.
- Do not load the stones too tightly. Over-filling of the stone compartment will
cause overheating of the resistors (= shorter service life) and slower heating up
of the sauna.
- Suitable stones for the stove are 4-7 cm in diameter.
- The stones shall cover the heating resistors completely.
AN UNDER-FILLED STONE COMPARTMENT WILL CAUSE A FIRE HAZARD!
ALWAYS CHECK THE SAUNA BEFORE SWITCHING ON THE STOVE.
4.4 Technical data of control unit
Temperature adjustment
range 40ºC-120ºC
Temperature display 20ºC-120ºC
In increments of 1ºC
Pre-selection time max. 24 h
In increments of 1/2 h
Max. Power On time 4 h
5.2 Lower board
voltage 400 V 3N 50 Hz
current 16 A
stove wattage max. 9 kW
sauna light max. 100 W
enclosure class IPX4
overheat protection 144ºC
Fuse 1 1A
Fuse 2 1A