EasyManua.ls Logo

National Instruments NI 6225 - Page 194

National Instruments NI 6225
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A Device-Specific Information
© National Instruments Corporation A-21 M Series User Manual
Figure A-8. Single-Ended Channels
When you set the source type to the GS position and software-configure the
device for single-ended input, each BNC connector provides access to two
single-ended channels, AI x and AI x+8. For example, the BNC connector
labeled AI 0 provides access to single-ended channels AI 0 and AI 8, the
BNC connector labeled AI 1 provides access to single-ended channels AI 1
and AI 9, and so on. Up to 16 single-ended channels are available in
single-ended measurement modes.
For information on how to connect your single-ended signals, AI GND,
and/or AI SENSE, refer to the Connecting Analog Input Signals section of
Chapter 4, Analog Input. For a detailed description of each signal, refer to
the I/O Connector Signal Descriptions section of Chapter 3, Connector and
LED Information.
Analog Output
You can access analog output signals on the BNC connectors labeled AO 0
and AO 1. Figure A-9 shows the analog output circuitry on the USB-6221
BNC.
Figure A-9. Analog Output Circuitry
Refer to the Connecting Analog Output Signals section of Chapter 5,
Analog Output, for more information.
Ground Ref.
Source (GS)
AI x
+
AI x+8
USB-62xx BNC Device
AO
x
AO GND