Appendix A Device-Specific Information
© National Instruments Corporation A-95 M Series User Manual
SCXI Accessories
SCXI is a programmable signal conditioning system designed for
measurement and automation applications. To connect your M Series
device to an SCXI chassis, use the SCXI-1349 adapter and an
SHC68-68-EPM cable.
Use Connector 0 of your M Series device to control SCXI. Connector 1
cannot be used to control SCXI.
SCC Accessories
SCC provides portable, modular signal conditioning to your DAQ system.
To connect your M Series device to an SCC module carrier, such as the
SC-2345, SC-2350, or SCC-68, use an SHC68-68-EPM shielded cable.
Use Connector 0 of your M Series device to control an SCC module carrier.
Connector 1 cannot be used with SCCs.
Refer to the SCC Advisor, available by going to
ni.com/info and
entering the info code
rdscav, for more information.
BNC Accessories
Using a BNC Accessory with Connector 0
Connector 0 of your device is compatible with several BNC accessories:
• BNC-2110—Provides BNC connectivity to all analog signals, some
digital signals, and spring terminals for other digital signals
• BNC-2111—Provides BNC connectivity to 16 single-ended analog
input signals, two analog output signals, five DIO/PFI signals, and the
external reference voltage for analog output
• BNC-2120—Similar to the BNC-2110, and also has a built-in function
generator, quadrature encoder, temperature reference, and
thermocouple connector
• BNC-2090A—Desktop/rack-mountable device with 22 BNCs for
connecting analog, digital, and timing signals
You can use the SHC68-68-EPM shielded cable, to connect Connector 0 of
your DAQ device to BNC accessories.