Appendix B Timing Diagrams
© National Instruments Corporation B-7 M Series User Manual
Figure B-5. AI Timing Clocks Timing Diagram
Table B-2. AI Timing Clocks Timing
Time Description Line Min (ns) Max (ns)
t
2
Minimum Pulse Width 12.5
t
3
Minimum Period 50.0
t
4
Delay to Sample Clock Timebase PFI 3.8 9.3
RTSI 3.5 9.0
STAR 3.0 6.4
t
5
Delay to Sync Sample Clock Timebase PFI 3.4 8.5
RTSI 3.2 8.3
STAR 2.7 5.6
t
6
Delay to Convert Clock Timebase PFI 4.1 10.2
RTSI 3.9 9.9
STAR 3.4 7.3
t
7
Delay to Sync Convert Clock
Timebase
PFI 3.6 8.9
RTSI 3.3 8.6
STAR 2.9 6.0
_i
Sync Convert
Clock Timebase
Sample
Clock Timebase
Sync Sample
Clock Timebase
Convert
Clock Timebase
t
2
t
2
t
3
t
4
t
5
t
7
t
6