EasyManua.ls Logo

National Instruments NI 6225 - Page 332

National Instruments NI 6225
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B Timing Diagrams
© National Instruments Corporation B-9 M Series User Manual
Figure B-7. Convert Clock Timing Diagram
Figure B-8. Convert Clock and Any Internal Signal Timing Diagram
Table B-3. Convert Clock Timing
Time Description Line Min (ns) Max (ns)
t
8
Delay from _i to Sync Convert Clock
Timebase
PFI 6.4 15.9
RTSI 6.0 15.6
STAR 5.7 12.9
t
9
Delay from _i to Convert Clock
Timebase
PFI 16.2 39.1
RTSI 16.0 38.8
STAR 15.5 36.1
t
10
Delay from Convert Clock Timebase to
p_AI_Convert
6.0 13.0
t
11
Delay from Convert Clock Timebase to
Convert Clock, when exported to an
external terminal (POUT)
PFI 4.6 10.8
RTSI 4.6 10.5
_i
POUT
Sync Convert Clock Timebase
Convert Clock Timebase
p_AI_Convert
t
8
t
9
t
10
t
11
_i
p_AI_Convert
t
12

Table of Contents

Related product manuals