EasyManua.ls Logo

National Instruments NI sbRIO-961 Series

National Instruments NI sbRIO-961 Series
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NI sbRIO-961x/9612XT/963x/9632XT/964x/9642XT 48 ni.com
Example power requirement calculations:
For an NI sbRIO-9642/9642XT with three installed board-only C
Series modules, 20 mA total current through the 3.3 V DIO pins, and
1 A of current through the 5 V output, calculate the total power
requirement as follows:
P
int
= 8.00 W
P
CSer
= 3.30 W
P
DIO
= 0.08 W
P
5V
= 5.55 W
Adding 20% for transient conditions, 16.93 W × 1.2 = 20.32 W
Total power requirement = 20.32 W
For an sbRIO-9612/9612XT with one installed board-only C Series
module, 330 mA total current through the 3.3 V DIO pins, and no 5 V
output used, calculate the total power requirement as follows:
P
int
= 7.50 W
P
CSer
= 1.10 W
P
DIO
= 1.28 W
P
5V
= 0.00 W
Adding 20% for transient conditions, 9.88 W × 1.2 = 11.86 W
Total power requirement = 11.86 W
Backup battery........................................3 V lithium coin cell,
BR2032 (–40 to 85 °C)
Safety Voltages
Connect only voltages that are within this limit.
V terminal to C terminal.........................35 VDC max,
Measurement Category I
Measurement Category I is for measurements performed on circuits not
directly connected to the electrical distribution system referred to as
MAINS voltage. MAINS is a hazardous live electrical supply system that
powers equipment. This category is for measurements of voltages from
specially protected secondary circuits. Such voltage measurements include
signal levels, special equipment, limited-energy parts of equipment,