NI sbRIO-961x/9612XT/963x/9632XT/964x/9642XT 50 ni.com
Environmental
The NI sbRIO-96xx/96x2XT is intended for indoor use only.
Ambient temperature in enclosure
(IEC 60068-2-1, IEC 60068-2-2)
NI sbRIO-961x/963x/964x...............–20 to 55 °C
NI sbRIO-96x2XT ...........................–40 to 85 °C
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ...........–40 to 85 °C
Operating humidity
(IEC 60068-2-56) ...................................10 to 90% RH, noncondensing
Storage humidity (IEC 60068-2-56).......5 to 95% RH, noncondensing
Maximum altitude...................................2,000 m
Pollution Degree (IEC 60664) ................2
Indoor use only
Physical Characteristics
Torque for screw terminals on J3 ...........0.5 to 0.6 N · m
(4.4 to 5.3 lb · in.)
Weight
NI sbRIO-961x/9612XT..................266.5 g (9.4 oz)
NI sbRIO-963x/9632XT..................269.3 g (9.5 oz)
NI sbRIO-964x/9642XT..................292.0 g (10.3 oz)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com