EasyManua.ls Logo

National Instruments PCI E Series - Page 81

National Instruments PCI E Series
162 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Programming
PCI E Series RLPM 4-18
©
National Instruments Corporation
4. Call the function Number_of_Scans to load the number of scans.
Joint_Reset_Register
AI configuration start = 1;
AI_SC_Load_A_Registers (24 bits)
Number of posttrigger scans -1 = 4;
AI_Command_1_Register
AI SC Load = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
5. The function
AI_Scan_Start selects the scan start event.
Joint_Reset_Register
AI configuration start = 1;
AI_Start_Stop_Select_Register
Start edge = 1;
Start sync = 1;
AI_SI_Load_A_Registers (24 bits)
AI SI special ticks -1 = 1;
AI_Command_1_Register
AI SI load = 1;
AI_SI_Load_A_Registers (24 bits)
AI SI ordinary ticks -1 = 19999;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
6. Perform Analog Input Example 1 Step 11.
7.
Convert_Signal selects the convert signal for the acquisition.
Joint_Reset_Register
AI configuration start = 1;
AI_SI2_Load_A_Register
AI SI2 special ticks -1 = 1999;
AI_SI2_Load_B_Register
AI SI2 ordinary ticks -1 = 1999;
AI_Mode_2_Register
AI SI2 reload mode = 1;
AI_Command_1_Register
AI SI2 load = 1;