USRP-2901 Front Panel, Back Panel, and LEDs
Front Panel
NI USRP-2901
70 MHz–6 GHz
ESD
SENSITIVE
RF 0
TX1 RX1
RX2
RF 1
TX1 RX1RX2
Designed by Ettus Research
TX OUTPUT MAX +20 dBm, RX INPUT MAX –15 dBm, ALL RF PORTS 50
Ω
Table 4. Connector Descriptions
Connector Description
RF 0 TX1 RX1 Input and output terminal for the RF signal. TX1 RX1 is an SMA (f)
connector with an impedance of 50 Ω and is a single-ended input or output
channel.
RX2 Input terminal for the RF signal. RX2 is an SMA (f) connector with an
impedance of 50 Ω and is a single-ended input channel.
RF 1 RX2 Input terminal for the RF signal. RX2 is an SMA (f) connector with an
impedance of 50 Ω and is a single-ended input channel.
TX1 RX1 Input and output terminal for the RF signal. TX1 RX1 is an SMA (f)
connector with an impedance of 50 Ω and is a single-ended input or output
channel.
USRP-2900/2901 Getting Started Guide | © National Instruments | 13