NAUTILUS MINI
- 19 - | P a g e
Edition December 2014
Do not disconnect charging hose before purging the pressure in the compressor.
How to deal with emergencies during air filling
If emergencies happened during the charging process
Power failure
Power cutoff due to overload
Sudden halt of compressor
1. Shut off the main switch of the compressor immediately and bring the equipment to a total stop.
2. Simultaneously, shutoff the charging valve on the cylinder.
Once the charging process has ended, the condensate drain valve need to be open to discharge the
condensate. After purging, close the condensate drain valve to avoid moisture from entering the equipment,
causing corrosion and rusting, which affects the equipment lifespan.